China ARM5 series thermal magnetic type double-breaker mccb 200ka icu=ics Thermal ajustable type mccb 400VAC/415VAC/550VAC/ 690VAC/800VAC400A 630A 3/4 Poles Manufacturer and Supplier | TCT

ARM5 series thermal magnetic type double-breaker mccb 200ka icu=ics Thermal ajustable type mccb 400VAC/415VAC/550VAC/ 690VAC/800VAC400A 630A 3/4 Poles

Short Description:

Rated Current : 400A、500A、630A

Number Of Poles : 3P / 4P

Rated Working Voltage : 400V/690V


Product Detail

Product Tags

MCCB Highlights

The reasonable structure design of moving and fixed contacts makes the short circuit peak value and energy of this series of products I²t much smaller than expected

Working principle: the current flows in from the fixed contact
1, flows out from the fixed contact
2, through the moving, fixed silver contact and the moving contact. The moving contact quickly disconnects under the action of strong electric repulsion force (Holm force and Lorentz force) to improve the breaking speed.

Air blowing design: when the short circuit large current occur in the circuit, the gas producing parts will generate other gas under the high temperature of the arc, the air pressure in the contact unit box increases rapidly, and a high-speed air flow can be formed through the air outlet of the arc extinguishing chamber, which can effectively extinguish the arc.

ARM5

Main performance index of ARM5 series circuit breaker

Model ARM5-630
Rated current In (A) 400A/500A/630A
Rated current of frame size Inm (A) 630A
Usage category Category A
Rated ultimate short-circuit breaking capacity level L M H
Number of poles (P) 3P 4P 3P 4P 3P 4P
Rated working voltage Ue (V) 400V/415V
Rated ultimate short-circuit breaking capacity Icu (kA) 85kA 150kA 200kA
Rated service short-circuit breaking capacity Ics (kA) 85kA 150kA 200kA
Rated working voltage Ue (V) 550V/690V
Rated ultimate short-circuit breaking capacity Icu (kA) 35kA 50kA 65kA
Rated service short-circuit breaking capacity Ics (kA) 35kA 50kA 65kA
Rated insulation voltage Ui (V) 1000V
Rated impulse withstand voltage Uimp (V) 8kV
Mechanical life (time) 7000
Electrical life (time) 400ln 1000
Arcing distance (mm) 0
Release type Thermomagnetic
W*L*H (mm) W 140 185 140 185 140 185
L 123.5
H 123.5

Overall and installation dimensions of circuit breaker

Circuit breaker 630 frame size installation safety interval

■ ARM5-630 front panel wiring (3P/4P)
X-X, Y-Y are the center of three-pole circuit breaker

Model H H1 H0 B C D
ARM5-630 123.5 167.1
ARM5E-630 123.5 167.1
ARM5EHU-630 123.5 167.1

MCCB Production Line Real Showing

01

mccb parts device

2020/08/05
Risus commodo viverra maecenas accumsan lacus vel facilisis.
view more
01

mccb moulding metal stamping production line

2020/08/05
Risus commodo viverra maecenas accumsan lacus vel facilisis.
view more
01

mccb parts processing device

2020/08/05
Risus commodo viverra maecenas accumsan lacus vel facilisis.
view more
01

mccb parts device copper

2020/08/05
Risus commodo viverra maecenas accumsan lacus vel facilisis.
view more
01

mccb molding office

2020/08/05
Risus commodo viverra maecenas accumsan lacus vel facilisis.
view more
01

mccb team

2020/08/05
Risus commodo viverra maecenas accumsan lacus vel facilisis.
view more
01

mccb automatic assembling device

2020/08/05
Risus commodo viverra maecenas accumsan lacus vel facilisis.
view more
01

mccb moulding metal stamping warehouse

2020/08/05
Risus commodo viverra maecenas accumsan lacus vel facilisis.
view more
010203040506

  • Previous:
  • Next:

  • Write your message here and send it to us